<LOGO>
FM Transmitter Measurement Report
Created: 2024-01-06 16-55-06
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
104.20 MHz 5/5, 54 dBuV RTL
Pilot RDS Phase Difference
0.0 kHz 3.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
5 kHz 70 kHz 19109 0,4344
Modulation Power
Limit Measuring Tolerance
9,0 dBr 1,0 dBr
MIN AVE MAX % above 10,0 dBr
dBr dBr dBr -1,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 1 2 16:55, 6.01.2024
RT
-
AF EON
95.3, 99.8, 100.4, 101.3, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 105.0, 105.1, 106.0 MHz -
FM Scope Station: 104.20 MHz, signal: 5/5 (54 dBuV) Max at: 70 kHz MIN: 5 kHz % above 75 kHz: 0,4344 Acquired: 2024/01/06 16:54:02 Total samples: 19109 Equivalent time: 0:15:55 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 0,0 dBr MIN: 0,0 dBr AVE: 0,00 dBr % above 10,0 dBr: -1,0 Last value: Station: 101.50 MHz, signal: 5/5 (63 dBuV) 16:56 16:57 16:58 16:59 17:00 0 50 100 Dev. MAX [kHz] -1 0 1 Pm [dBr] 0 5 Signal Quality